Oct 26, 2025 Leave a message

C11000-Copper-Technical-Specification.pdf

Type K, L and M C11000 Copper Straight Tubes for Plumbing

C11000 Copper Straight Tube for Plumbing

C11000 is electrolytic tough pitch copper, the general-purpose high-conductivity grade containing 99.90% copper minimum with roughly 0.02-0.04% oxygen. It is supplied as straight lengths and as coils, and it is the material behind the familiar K, L, M and DWV classifications used for water, heating and drainage systems. Straight tube in 20 ft (about 6 m) lengths is the normal delivery form for above-ground distribution piping, while coils serve services that are bent on site.

The classification is simple to use. Type K has the heaviest wall, Type L a medium wall and Type M a thin wall, with all three intended for pressure service; DWV tube is a separate, thinner classification for drainage, waste and vent lines that are not pressurised. Choosing between them is a matter of buried depth, pressure and the consequences of a leak rather than of alloy content.

Type K, L and M Wall Thickness Comparison

Nominal size Type K wall Type L wall Type M wall
1/2 in 0.049 in (1.24 mm) 0.040 in (1.02 mm) 0.028 in (0.71 mm)
3/4 in 0.065 in (1.65 mm) 0.045 in (1.14 mm) 0.032 in (0.81 mm)
1 in 0.065 in (1.65 mm) 0.050 in (1.27 mm) 0.035 in (0.89 mm)

Wall thickness increases with nominal size within each type, and the ordering of the types never changes: for a given size, K is heavier than L, and L is heavier than M. The practical consequences are as follows.

Type K - heavy wall. Selected for underground burial, high-pressure circuits and services where mechanical damage or soil corrosion is a risk, because the extra wall thickness provides a larger corrosion allowance and greater resistance to crushing.

Type L - medium wall. The general plumbing and heating workhorse, used for potable water, hydronic heating and many light industrial lines, and usually available annealed in coils for bending.

Type M - thin wall. Used for residential water systems, exposed interior piping and low-pressure duties where the wall thickness allowed by the applicable code is sufficient.

Type DWV - drainage wall. Designed for drainage, waste and vent applications and not permitted for pressure service.

Specifications and Material Considerations

Seamless copper water tube is specified under ASTM B88, which covers Types K, L and M in drawn temper and, for the sizes supplied, in annealed temper. Copper drainage tube is covered by ASTM B306, and seamless copper pipe for general piping use by ASTM B75. Medical gas and refrigeration lines use the same wall thickness families under ASTM B280, where cleanliness and non-reactive internal surfaces are added requirements.

One point is often overlooked: although C11000 ETP copper offers the best electrical and thermal conductivity, most potable water tube is actually supplied as C12200, the phosphorus-deoxidised high-residual-phosphorus grade. C12200 contains about 0.015-0.040% phosphorus, which removes the oxygen that would otherwise form copper oxide and generate steam porosity when the joint is brazed in a reducing atmosphere. Where the assembly is to be welded or brazed, or where the tube will be bent and annealed after forming, C12200 is the safer selection and both grades are permitted by the water tube specification. C11000 remains the natural choice for busbar, strip and general electrical duty.

Pressure, Temper and Code Requirements

Copper water tube carries no single universal pressure rating, because the allowable working pressure depends on the wall thickness of the type selected, the temperature and the design basis of the applicable code, such as ASME B31.1 for power piping or ASME B31.9 for building services. Designers therefore derive the allowable pressure from the code and the selected type rather than quoting a catalogue figure: for the same nominal size, Type K always yields the highest allowable pressure and Type M the lowest.

Temper selection follows the installation method. Drawn (hard) tube is used for straight runs where rigidity and appearance matter, and it is joined with capillary fittings. Annealed (soft) tube is supplied in coils for bending around obstructions and for underground runs where joints should be minimised. Bending of hard tube is not recommended without annealing, because the material will crack at a tight radius.

Installation and Maintenance Practice

Inspect regularly for leaks, corrosion and signs of mechanical wear, since early detection prevents larger failures in concealed runs.

Clean the exterior with a mild soap solution and water, and avoid aggressive chemicals that attack the metal or leave residues on the tube surface.

Protect tube exposed to moisture or aggressive soil with a suitable protective coating or sleeving, and keep copper away from direct contact with steel and with new concrete, which can promote attack.

Solder or braze joints properly, using lead-free solder to ASTM B32 such as a tin-copper or tin-silver alloy for potable water work, and flush flux residues from the bore after assembly.

Support and space the tube at the intervals required by the applicable plumbing code to control thermal movement and vibration.

Monitor temperature: although the melting point of copper is 1084 °C, a plumbing system is limited by the solder or brazing filler used, since a tin-based solder joint softens far below the boiling point of water and must not be used where the joint will be overheated.

Frequently Asked Questions

Q: What is the difference between Type K, Type L and Type M copper tube?
The difference is wall thickness. Type K has the heaviest wall and is used for underground and high-pressure work, Type L is the medium-wall general plumbing and heating grade, and Type M is the thin-wall grade for exposed low-pressure residential piping.

Q: Is C11000 copper tube suitable for potable water?
C11000 ETP copper is permitted by the water tube specification, but in practice C12200 phosphorus-deoxidised copper is preferred for potable water because its low oxygen content keeps brazed and welded joints sound. Both grades are covered by ASTM B88.

Q: Which standard covers copper water tube?
ASTM B88 covers seamless copper water tube in Types K, L and M, ASTM B306 covers copper drainage tube, and ASTM B75 covers seamless copper pipe. Medical gas and refrigeration tube of the same wall families is covered by ASTM B280.

Q: Can copper tube be buried underground?
Yes, and Type K is the usual choice because its heavier wall provides a larger corrosion allowance and greater resistance to crushing and external damage. The tube should be protected from aggressive soils and from contact with dissimilar metals.

Q: What solder or brazing filler should be used for copper tube joints?
Use lead-free solder to ASTM B32, such as tin-copper or tin-silver alloys, for potable water, and silver-bearing brazing filler to AWS A5.8 where higher joint strength or higher service temperature is required. Flux residues must be flushed from the tube bore after assembly.

Q: Can straight C11000 copper tube be bent on site?
Hard drawn straight tube should not be bent without annealing, because it will crack at tight radii. Annealed tube is supplied in coils for bending, or the straight tube can be locally annealed before forming, followed by restoration of the required temper.