What Is Cu-ETP C11000 Square Tube?
Cu-ETP is electrolytic tough pitch copper, designated UNS C11000, with a minimum copper content of 99.90 %. The oxygen remaining in the metal is present as cuprous oxide particles dispersed in the copper matrix, and it is the grade from which most electrical conductors and general-purpose copper tube are made. Square and rectangular seamless tube is produced from the same material by drawing over a shaped mandrel, so the section is formed without a seam and the internal surface is free of a weld bead.
Square tube is chosen where a flat face is needed for mounting, where a compact bundle gives a higher heat transfer surface per unit volume than round tube, or where the section itself carries current. In heat exchangers the flat faces also provide more stable contact with plates and clamps, which simplifies assembly of plate-type and conduction-cooled units.
Composition and Typical Physical Properties
| Item | Value |
|---|---|
| Copper (Cu) | 99.90 % min |
| Oxygen (O) | Present as cuprous oxide; typically 0.02-0.04 % |
| Other elements, total | Limited by the specification for C11000 |
| Density | 8.94 g/cm³ |
| Thermal conductivity | about 388 W/(m K) at 20 C |
| Electrical conductivity | 100 % IACS min for annealed material |
| Modulus of elasticity | about 117 GPa |
| Melting point | about 1083 C |
The specification requirements for the grade, including conductivity and the mechanical values for each temper, are those of the applicable copper product standard, such as ASTM B75/B75M for seamless tube and ASTM B152/B152M for plate, sheet and strip. Copper tube for heat transfer service is normally supplied in the annealed temper for bending and expansion, with hard tempers used where stiffness rather than formability is required.
Square and Rectangular Tube Sizes and Tolerances
Seamless square and rectangular copper tube is drawn to order across the range below; wall thickness and corner radius are the two dimensions that most often decide whether the section works in a given assembly.
| Dimension | Typical range | Notes |
|---|---|---|
| Outside dimension, square | 10 mm to 100 mm | Larger sections available to agreement |
| Wall thickness | 1.0 mm to 10 mm | Wall affects pressure rating and current capacity |
| Corner radius | Per drawing or to the standard radius for the size | Controls fit in a housing |
| Straight length | Up to about 6 m | Cut lengths to order |
| Straightness and twist | Within the limits of the applicable tube specification | Verified on the finished length |
| End condition | Squared, deburred, capped on request | Protects the bore in transit |
Because the section is drawn rather than welded, the wall is uniform around the perimeter and the corners are fully dense, which matters for both pressure containment and electrical current distribution.
Manufacturing Route and Inspection
Production starts from continuously cast or extruded copper, which is rolled, annealed and then drawn to the finished section through shaped dies and mandrels. Intermediate anneals restore ductility, and the final anneal sets the temper. Inspection of tube for heat transfer and conductor duty typically includes the following:
Chemical analysis of the cast lot, confirming that copper content and residual elements are within the grade limits.
Dimension and wall-thickness gauging along the length, including corner radius where specified.
Eddy-current examination to ASTM E243 for tube ordered for heat exchanger service, to detect laps, cracks and inclusions.
Pneumatic or hydrostatic pressure test to the pressure required by the order.
Tension and, where required, bend or flattening tests to confirm the temper.
Results are reported on a mill certificate traceable to the heat number, which is the document that allows the tube to be released for a coded exchanger or a busbar assembly.
Applications
Heat exchanger elements in plate, conduction-cooled and compact units where a square face simplifies clamping.
Induction heating and melting coils, where the flat section improves coupling and allows closer winding.
Conductor bars, terminals and short bus connections inside switchgear and transformers.
Electrode holders, resistance welding shunts and current-carrying structural parts.
Thermal transfer parts in refrigeration, electronics cooling and process equipment.
General engineering sections where high conductivity, formability and corrosion resistance are all required.
The same grade is widely used in domestic and industrial plumbing tube, which is why square and rectangular sections in C11000 are available with a consistent metallurgical history and a well understood behaviour in service.
Fabrication and Selection Notes
Cu-ETP is ductile and easy to bend, flare and expand, but its oxygen content sets one firm limit in fabrication: the grade is not suitable for heating in a reducing or hydrogen-bearing atmosphere at high temperature. Hydrogen diffuses into the copper and reacts with the cuprous oxide particles to form steam, which generates internal pressure and cracks the metal along the grain boundaries. This effect is the reason why tube and rod that must be brazed, sintered or annealed in a reducing atmosphere are specified in oxygen-free grades such as C10200 instead.
Bend with a radius suitable for the wall thickness, and anneal only if the drawing requires a tighter radius than the temper allows.
When brazing, purge the bore with dry nitrogen to prevent internal oxide scale, and use a flux and filler matched to copper.
Where a reducing furnace atmosphere is part of the process, specify oxygen-free copper rather than Cu-ETP.
Protect the annealed surface during storage and handling; copper tarnishes readily and a heavy oxide layer must be removed before a joint is brazed.
For current-carrying sections, allow a temperature rise that keeps both the joint and the copper within the design limits of the assembly.
Selection between round and square section is usually an assembly decision rather than a metallurgical one, because thermal and electrical conductivity per unit of cross-sectional area are the same in either shape.
FAQ
Q: What does Cu-ETP mean?
ETP stands for electrolytic tough pitch. The copper is electrolytically refined and then melted and cast in air, with the oxygen content controlled so that residual oxygen appears as cuprous oxide. It is the standard high-conductivity copper grade, designated UNS C11000 with a minimum copper content of 99.90 %.
Q: Does square tube have the same properties as round tube?
Yes. The alloy, temper and conductivity are identical; only the cross-sectional shape differs. The square form gives a flat face for clamping and a more compact bundle, while round tube is easier to roll into a tube sheet and is usually lower in cost for the same wall area.
Q: Why can Cu-ETP not be used in a hydrogen atmosphere?
Cuprous oxide in the copper reacts with hydrogen at high temperature to form steam inside the metal, causing internal cracks known as hydrogen embrittlement. Oxygen-free grades such as C10200 contain almost no oxide and are specified for brazing, annealing or service in reducing atmospheres.
Q: What conductivity should be expected from C11000?
Annealed C11000 meets 100 % IACS minimum conductivity, corresponding to about 58 MS/m. This is one of the reasons the grade is used both as an electrical conductor and as a heat transfer material.
Q: How is the tube tested before delivery?
By dimensional and visual inspection, eddy-current examination when ordered for heat transfer service, pressure testing, and mechanical tests of the temper. Chemical composition is verified on the cast lot and reported on the mill certificate.
Q: Can square copper tube be bent or coiled?
It can be bent in the annealed temper to a radius that depends on the size and wall thickness, but a square section will distort if bent too tightly. For tight coils, round tube in the same grade is normally used instead.