C10100 OFE Thick-Walled Copper Conductor Pipe for Bus and Vacuum Systems

What C10100 OFE Thick-Walled Conductor Pipe Is

C10100 OFE is oxygen-free electronic copper, a 99.99% pure copper with an oxygen content held at or below 0.0005%. In the thick-walled pipe form it is used as a rigid conductor: a heavy-wall tube that carries current, heat or microwave energy along a defined path instead of relying on a flexible cable or a flat busbar. The metal is melted and poured in the presence of carbon or carbonaceous gas so that the oxygen is absorbed by the carbon rather than left in solution, and because no deoxidiser remains in the melt, the finished pipe averages 101% IACS conductivity.

Oxygen-free high conductivity copper of this type, often written OFHC C101, is free from hydrogen embrittlement when it is heated in a reducing atmosphere, and unlike the lower-purity oxygen-free grade it can be certificated to the percentage of impurities in its composition.

Chemical Composition and Impurity Limits

Element Limit Purpose of the limit
Cu 99.99% minimum Sets the conductivity and thermal transport ceiling
O 0.0005% maximum Prevents steam voids and hydrogen embrittlement at grain boundaries
P 0.0003% maximum Phosphorus is the strongest conductivity killer in copper, so it is held far below alloying levels
Sb 0.0004% maximum Controls residual resistivity from antimony
As 0.0005% maximum Controls residual resistivity from arsenic
Te 0.0002% maximum Limits embrittling telluride inclusions

These are very low ceilings, and they are the reason the grade is bought with a certified chemical analysis rather than on conductivity alone. Two heats can both read 101% IACS while differing in vacuum behaviour and brazing response, and the impurity certificate is what separates them.

Conductivity, Thermal and Vacuum Performance

Electrical conductivity: 101% IACS average, the highest of the commercial coppers, which allows a smaller cross-section for the same current and therefore a lighter conductor run.

Thermal conductivity: about 398 W/(m·K) at a 20 °C reference, so the same pipe that carries current also carries heat away from a joint or a termination.

Vacuum behaviour: an extremely low outgassing rate, which makes the material suitable for components used inside high-vacuum systems such as particle accelerators.

Hydrogen service: safe for reducing-atmosphere brazing and annealing because there is no oxygen in the metal to form steam at grain boundaries.

In thick-wall form these properties matter more than they do in thin tube: the current crowds toward the surface, so the wall thickness is chosen for mechanical stiffness, for heat storage and for thread or flange support rather than for current-carrying area alone.

Tempers, Standards and Product Forms

C10100 conductor pipe is normally ordered in the standard tempers defined by ASTM B601, the specification for temper designations of copper and copper alloys:

Temper Condition Applicable tube standards
O50 Light-drawn, annealed ASTM B111, ASTM B68, ASTM B280
O60 Soft annealed ASTM B111, ASTM B68, ASTM B280
H55 Light drawn, hard ASTM B111, ASTM B68, ASTM B280
H58 Drawn, hard ASTM B111, ASTM B68, ASTM B280

The same composition is supplied across a wide range of mill forms, each with its own specification: ASTM F68 for rod, bar, shapes and forgings; ASTM B152 for sheet, strip, plate and rolled bar; ASTM B187 for bus bar, rod and shapes; ASTM B188 for pipe and bus; ASTM B272 for hard-drawn wire; ASTM B75 for seamless tube; ASTM B447 for welded tube; ASTM B640 for welded tube for air conditioning and refrigeration service; and ASTM B359 for finned tube. Bus pipe is normally ordered to ASTM B188 with the wall thickness set by the mechanical and thermal duty rather than by the nominal current.

Material can be supplied cut to specification by bar saw, shear, precision plate saw or water jet, which is usually the practical route for short bus runs and for waveguides that need tight end preparation.

Applications for Thick-Walled OFE Copper Pipe

Electrical and electronic engineering: rigid conductors for high-frequency communication lines, waveguide tube, vacuum electronic devices, integrated circuit lead frames, and transformer and motor windings.

Energy sector: conductor strip for solar cells and conductive components for the nuclear power industry.

High-precision instruments: core conductor material for high-fidelity audio cable and precision measuring instruments.

Vacuum systems: accelerator and cavity components where an extremely low outgassing rate is mandatory.

Bus and switchgear work: heavy-wall bus pipe and bus bar where a stiff, self-supporting conductor is required.

Fabrication Notes

Brazing and welding are done in a reducing or inert atmosphere where possible; because C10100 contains no oxygen, hydrogen-bearing furnace atmospheres are acceptable.

Annealing and forming must account for the very high thermal conductivity, which draws heat away from the joint and makes local heating slower than on alloy copper.

Cut ends and threaded sections should be deburred and kept clean, because copper oxide films on a conductor surface raise contact resistance at a clamped joint.

Support spacing on long horizontal runs should be set by the stiffness of the chosen temper: the light-drawn tempers deflect less than the soft annealed tempers.

Frequently Asked Questions

Q: What does C10100 OFE copper pipe contain?
At least 99.99% copper with oxygen at or below 0.0005%, and tightly limited residuals including phosphorus at 0.0003% maximum, antimony at 0.0004%, arsenic at 0.0005% and tellurium at 0.0002%.

Q: What conductivity does the pipe deliver?
101% IACS average, with a resistivity low enough that the same wall can also act as a heat path with a thermal conductivity of about 398 W/(m·K).

Q: Which standards apply to C10100 conductor pipe?
ASTM B188 for pipe and bus, ASTM F68 for rod, bar, shapes and forgings, ASTM B152 for plate and sheet, ASTM B187 for bus bar and rod, ASTM B75 and ASTM B447 for seamless and welded tube, with tempers designated under ASTM B601.

Q: What do the tempers O50, O60, H55 and H58 mean?
They are ASTM B601 temper designations: O50 and O60 are the annealed light-drawn and soft conditions used for forming, and H55 and H58 are the harder drawn conditions used where a stiffer, self-supporting wall is needed.

Q: Can C10100 be heated in hydrogen?
Yes. It is free from hydrogen embrittlement because it contains no oxygen to form steam at grain boundaries, which is why it can be brazed or annealed in reducing atmospheres.

Q: Why use thick-wall pipe instead of a flat busbar?
A heavy-wall pipe is stiffer, carries a cooling or vacuum path inside it, and gives a closed, cleanable surface, which suits waveguide runs and vacuum components where a flat bar cannot be used.

Q: Is C10100 the same as C10200?
Both are oxygen-free coppers, but C10100 is produced and certified to a tighter impurity breakdown, so it is specified where the exact residual level matters.