Air Conditioning Copper Pipes
Shape Type:Straight Round,Square,Rectangular,Coil,Oval,Half-Round
Wall Thickness:0.2-3mm
Out Diameter:3mm-100mm
Length:1M-6M or As your demand (Pancake copper tube usual length: 15 meters)
Temper:Soft(M),Half Soft(M2) and Half Hard(Y2)
Surface Treatment:Bright and Clean
Package Type:Plastic Film With Plastic Caps on the both ends and Wooden Case Carton Package or as your demand
Gnee Steel (Tianjin) Co., Ltd. is one of the most professional manufacturers and suppliers of air conditioning copper pipes in China, also supports customized service. Welcome to buy discount air conditioning copper pipes for sale here from our factory. Quality products and reasonable price are available.
Copper tubes are widely used in air conditioning refrigerant pipelines due to their high thermal conductivity, corrosion resistance and processing performance. Copper tubes can withstand greater working pressure, have a longer service life, and are superior to other materials in cooling effect, so they have become the preferred material for air conditioning systems.
Why do air conditioners use copper tubes instead of stainless steel tubes?

Thermal conductivity crushing
The thermal conductivity of copper is 25 times that of stainless steel, and the refrigerant can instantly complete heat exchange when it flows through the copper tube. This high-efficiency heat conduction directly determines the cooling speed of the air conditioner, and the "insulation" property of stainless steel is actually a disadvantage in the refrigeration system.
Ductility rescue construction
When the installer manually bends the copper tube at the corner of the wall, the copper tube will only deform but not crack. If the stainless steel tube encounters this situation, it is very easy to produce metal fatigue cracks, and the risk of refrigerant leakage in the later stage will increase sharply, and repairing it once is equal to the cost of replacing a new machine.


Surface protection comes with armor
After the surface of the copper tube is oxidized, a dense oxide film is generated to prevent further corrosion, and the interior remains smooth after twenty years of use. Stainless steel is prone to intergranular corrosion in a humid salt spray environment, especially in the external unit connection pipe section of high-rise residential buildings in coastal cities. This situation is particularly fatal.
Cost is not the only obstacle
Although stainless steel materials are about 30% cheaper, their processing requires complex processes such as laser welding. The equipment investment for a set of stainless steel pipe production line is 8 times that of copper pipes, and weld flaw detection must be performed after bending, so the overall production cost is higher.

Comparison of copper pipes used in air conditioners and other materials
| Comparison Item | Copper Pipe | Aluminum Pipe | Galvanized Steel Pipe | PVC Pipe |
|---|---|---|---|---|
| Thermal Conductivity | Excellent (401 W/(m·K)) | Moderate (237 W/(m·K)) | Poor (50 W/(m·K)) | Very poor (0.19 W/(m·K)) |
| Corrosion Resistance | Naturally corrosion-resistant | Forms oxide layer, may corrode | Rusts when coating damaged | Chemically resistant but brittle |
| Mechanical Strength | High ductility, pressure-resistant | Soft, prone to deformation | Rigid but cannot bend | Low strength |
| Seal Integrity | Excellent welded joints | Requires special welding | Depends on flange connections | Glue joints may leak |
| Installation | Lightweight, easy to work with | Light but needs special tools | Heavy, complex installation | Light but fragile |
| Applications | Refrigerant lines, high-pressure | Low-pressure refrigerant | Water circulation systems | Drainage only |
| Lifespan | 20-30 years | 10-15 years | 5-10 years | 5-10 years |
| Environmental Impact | Fully recyclable | Recyclable but degrades | High maintenance pollution | Non-degradable |
| Cost | Higher cost | Lowest cost | Moderate cost | Lowest cost |
specific applications of copper pipes in air conditioning systems
Refrigerant Circulation Piping (Core Application)
High-pressure gas pipes between compressor and condenser
Liquid pipes between condenser and throttling device (expansion valve/capillary tube)
Low-pressure suction pipes between evaporator and compressor
Heat Exchanger Components
Coils inside condensers
Coils inside evaporators
Connection Piping
Connecting pipes between indoor and outdoor units
Branch pipes between branch joints and indoor units
Special Components
Inlet/outlet pipes for liquid receivers
Oil separator circuits
Microchannel Systems (New Applications)
Header pipes for microchannel heat exchangers




Chemical content of commonly used air conditioning copper tube grades
| U.S. Copper Grade | UNS Number | Chemical Composition | HVAC Applications |
|---|---|---|---|
| ACR Copper | C12200 | Cu ≥99.9%, P: 0.015-0.040% | Refrigerant lines, coils |
| DHP Copper | C12200 | Cu ≥99.9%, P: 0.015-0.040% | Heat exchangers |
| OF Copper | C10200 | Cu ≥99.95%, O: <0.0005% | Critical refrigerant circuits |
| DLO Copper | C12000 | Cu ≥99.9%, P: 0.004-0.012% | Small-diameter tubing |
| ETP Copper | C11000 | Cu ≥99.9%, O: 0.02-0.04% | Water piping, drains |
Copper Pipe Sizes for Air Conditioning
Insulated Copper Pipe Air Conditioning Straight length Form
| AC Copper Piping Internal working pressure at 150°F (65°C) |
O.D. in mm |
O.D. in inches |
WT in mm |
WT in inches |
Weight (kg) per metre |
Weight (kg) per foot |
|
|---|---|---|---|---|---|---|---|
| BAR | PSI | ||||||
| 120 | 1742 | 9.53 | 3/8″ | 0.8 | 0.031 | 0.194 | 0.059 |
| 90 | 1304 | 12.7 | 1/2″ | 0.8 | 0.031 | 0.266 | 0.081 |
| 90 | 1304 | 15.88 | 5/8″ | 1 | 0.039 | 0.41 | 0.125 |
| 60 | 868 | 19.05 | 3/4″ | 0.8 | 0.031 | 0.407 | 0.124 |
| 75 | 1086 | 19.05 | 3/4″ | 1 | 0.039 | 0.512 | 0.156 |
| 51 | 744 | 22.22 | 7/8″ | 0.8 | 0.031 | 0.476 | 0.145 |
| 64 | 930 | 22.22 | 7/8″ | 1 | 0.039 | 0.613 | 0.187 |
| 50 | 716 | 25.4 | 1″ | 0.88 | 0.035 | 0.59 | 0.18 |
| 56 | 814 | 25.4 | 1″ | 1 | 0.039 | 0.699 | 0.213 |
| 50 | 723 | 28.58 | 1-1/8″ | 1 | 0.039 | 0.768 | 0.234 |
| 50 | 716 | 31.75 | 1-1/4″ | 1.1 | 0.043 | 0.945 | 0.288 |
| 50 | 716 | 34.93 | 1-3/8″ | 1.21 | 0.048 | 1.151 | 0.351 |
| 50 | 716 | 38.1 | 1-1/2″ | 1.32 | 0.052 | 1.368 | 0.417 |
| 50 | 716 | 41.28 | 1-5/8″ | 1.43 | 0.056 | 1.601 | 0.488 |
| 50 | 720 | 44.45 | 1-3/4″ | 1.55 | 0.061 | 1.883 | 0.574 |
| 47 | 681 | 53.98 | 2-1/8″ | 1.78 | 0.07 | 2.601 | 0.793 |
Copper Tubes for Air Conditioner Soft Coil Form
| Copper Tubes For Air Conditioning Internal working pressure at 150°F (65°C) |
O.D. in mm |
O.D. in inches |
WT in mm |
WT in inches |
Weight (kg) per metre |
Weight (kg) per foot |
|
|---|---|---|---|---|---|---|---|
| bar | psi | ||||||
| 91 | 1319 | 6.35 | 1/4″ | 0.8 | 0.032 | 0.125 | 0.038 |
| 60 | 876 | 9.53 | 3/8″ | 0.8 | 0.032 | 0.194 | 0.059 |
| 45 | 656 | 12.7 | 1/2″ | 0.8 | 0.032 | 0.266 | 0.081 |
| 45 | 656 | 15.88 | 5/8″ | 1 | 0.04 | 0.413 | 0.126 |
| 38 | 546 | 19.05 | 3/4″ | 1 | 0.04 | 0.512 | 0.156 |
Maintenance measures for air-conditioning copper pipes
HVAC copper pipes
Plant and equipment










Packaging and shipping





Customer visits










GNEE is an enterprise engaged in the research, smelting and processing of copper and copper alloys. The factory covers an area of 350,000 square meters, and now has a series of production equipments such as vacuum induction furnace imported from the United States, vacuum consumable arc furnace made in Germany, 2800mm four-high reversible rolling mill, vacuum annealing furnace, and so on, which can customize the production of any size of plate within 2.6m * 16m, and the maximum length of a single pipe can reach 15m.
Meanwhile, we also have more than 100 sets of various testing instruments, the main equipment includes American non-destructive testing system, spectral analyzer, carbon and sulfur tester, universal testing machine, ultrasonic testing system, fatigue testing machine and so on.
With more than 10 years of export experience, our products are exported to USA, UK, Germany, France, Brazil, Japan, Korea, India, Vietnam, Australia, Philippines, Zambia, Indonesia and other countries.
Contact us today for a quotation:sales@gneesteel.com

Hot Tags: air conditioning copper pipes, China air conditioning copper pipes manufacturers, suppliers, factory
Previous
Heat Exchanger TubesNext
Copper WiresYou Might Also Like
Send Inquiry