Standard:ASTM B280,ASTM B68,ASTM B75,ASTM B88 JIS H3300 EN12735,AS1571
Shape Type:Straight Round,Square,Rectangular,Coil,Oval,Half-Round
Wall Thickness:0.2-3mm
Out Diameter:3mm-100mm
Length:1M-6M or As your demand (Pancake copper tube usual length: 15 meters)
Temper:Soft(M),Half Soft(M2) and Half Hard(Y2)
Surface Treatment:Bright and Clean
Package Type:Plastic Film With Plastic Caps on the both ends and Wooden Case Carton Package or as your demand
Send Inquiry
Chat Now
Product Introduction

Gnee Steel (Tianjin) Co., Ltd. is one of the most professional manufacturers and suppliers of air conditioning copper pipes in China, also supports customized service. Welcome to buy discount air conditioning copper pipes for sale here from our factory. Quality products and reasonable price are available.

 

Copper tubes are widely used in air conditioning refrigerant pipelines due to their high thermal conductivity, corrosion resistance and processing performance. Copper tubes can withstand greater working pressure, have a longer service life, and are superior to other materials in cooling effect, so they have become the preferred material for air conditioning systems.

Why do air conditioners use copper tubes instead of stainless steel tubes?
 
7291

Thermal conductivity crushing

The thermal conductivity of copper is 25 times that of stainless steel, and the refrigerant can instantly complete heat exchange when it flows through the copper tube. This high-efficiency heat conduction directly determines the cooling speed of the air conditioner, and the "insulation" property of stainless steel is actually a disadvantage in the refrigeration system.

Ductility rescue construction

When the installer manually bends the copper tube at the corner of the wall, the copper tube will only deform but not crack. If the stainless steel tube encounters this situation, it is very easy to produce metal fatigue cracks, and the risk of refrigerant leakage in the later stage will increase sharply, and repairing it once is equal to the cost of replacing a new machine.

7292
7293

Surface protection comes with armor

After the surface of the copper tube is oxidized, a dense oxide film is generated to prevent further corrosion, and the interior remains smooth after twenty years of use. Stainless steel is prone to intergranular corrosion in a humid salt spray environment, especially in the external unit connection pipe section of high-rise residential buildings in coastal cities. This situation is particularly fatal.

Cost is not the only obstacle

Although stainless steel materials are about 30% cheaper, their processing requires complex processes such as laser welding. The equipment investment for a set of stainless steel pipe production line is 8 times that of copper pipes, and weld flaw detection must be performed after bending, so the overall production cost is higher.

7294

 

Comparison of copper pipes used in air conditioners and other materials

 

 

Comparison Item Copper Pipe Aluminum Pipe Galvanized Steel Pipe PVC Pipe
Thermal Conductivity Excellent (401 W/(m·K)) Moderate (237 W/(m·K)) Poor (50 W/(m·K)) Very poor (0.19 W/(m·K))
Corrosion Resistance Naturally corrosion-resistant Forms oxide layer, may corrode Rusts when coating damaged Chemically resistant but brittle
Mechanical Strength High ductility, pressure-resistant Soft, prone to deformation Rigid but cannot bend Low strength
Seal Integrity Excellent welded joints Requires special welding Depends on flange connections Glue joints may leak
Installation Lightweight, easy to work with Light but needs special tools Heavy, complex installation Light but fragile
Applications Refrigerant lines, high-pressure Low-pressure refrigerant Water circulation systems Drainage only
Lifespan 20-30 years 10-15 years 5-10 years 5-10 years
Environmental Impact Fully recyclable Recyclable but degrades High maintenance pollution Non-degradable
Cost Higher cost Lowest cost Moderate cost Lowest cost

 

 

specific applications of copper pipes in air conditioning systems

 
 

Refrigerant Circulation Piping (Core Application)

High-pressure gas pipes between compressor and condenser

Liquid pipes between condenser and throttling device (expansion valve/capillary tube)

Low-pressure suction pipes between evaporator and compressor

 

Heat Exchanger Components

Coils inside condensers

Coils inside evaporators

 

Connection Piping

Connecting pipes between indoor and outdoor units

Branch pipes between branch joints and indoor units

 

Special Components

Inlet/outlet pipes for liquid receivers

Oil separator circuits

 

Microchannel Systems (New Applications)

Header pipes for microchannel heat exchangers

1
2
3
4

 

Chemical content of commonly used air conditioning copper tube grades

 

 

U.S. Copper Grade UNS Number Chemical Composition HVAC Applications
ACR Copper C12200 Cu ≥99.9%, P: 0.015-0.040% Refrigerant lines, coils
DHP Copper C12200 Cu ≥99.9%, P: 0.015-0.040% Heat exchangers
OF Copper C10200 Cu ≥99.95%, O: <0.0005% Critical refrigerant circuits
DLO Copper C12000 Cu ≥99.9%, P: 0.004-0.012% Small-diameter tubing
ETP Copper C11000 Cu ≥99.9%, O: 0.02-0.04% Water piping, drains

 

 

Copper Pipe Sizes for Air Conditioning

 

 

Insulated Copper Pipe Air Conditioning Straight length Form

AC Copper Piping Internal working
pressure at 150°F (65°C)
O.D. in
mm
O.D. in
inches
WT in
mm
WT in
inches
Weight (kg)
per metre
Weight (kg)
per foot
BAR PSI            
120 1742 9.53 3/8″ 0.8 0.031 0.194 0.059
90 1304 12.7 1/2″ 0.8 0.031 0.266 0.081
90 1304 15.88 5/8″ 1 0.039 0.41 0.125
60 868 19.05 3/4″ 0.8 0.031 0.407 0.124
75 1086 19.05 3/4″ 1 0.039 0.512 0.156
51 744 22.22 7/8″ 0.8 0.031 0.476 0.145
64 930 22.22 7/8″ 1 0.039 0.613 0.187
50 716 25.4 1″ 0.88 0.035 0.59 0.18
56 814 25.4 1″ 1 0.039 0.699 0.213
50 723 28.58 1-1/8″ 1 0.039 0.768 0.234
50 716 31.75 1-1/4″ 1.1 0.043 0.945 0.288
50 716 34.93 1-3/8″ 1.21 0.048 1.151 0.351
50 716 38.1 1-1/2″ 1.32 0.052 1.368 0.417
50 716 41.28 1-5/8″ 1.43 0.056 1.601 0.488
50 720 44.45 1-3/4″ 1.55 0.061 1.883 0.574
47 681 53.98 2-1/8″ 1.78 0.07 2.601 0.793

 

Copper Tubes for Air Conditioner Soft Coil Form

Copper Tubes For Air Conditioning Internal working
pressure at 150°F (65°C)
O.D. in
mm
O.D. in
inches
WT in
mm
WT in
inches
Weight (kg)
per metre
Weight (kg)
per foot
bar psi            
91 1319 6.35 1/4″ 0.8 0.032 0.125 0.038
60 876 9.53 3/8″ 0.8 0.032 0.194 0.059
45 656 12.7 1/2″ 0.8 0.032 0.266 0.081
45 656 15.88 5/8″ 1 0.04 0.413 0.126
38 546 19.05 3/4″ 1 0.04 0.512 0.156

 

 

Maintenance measures for air-conditioning copper pipes

 

 

 

HVAC copper pipes

It is necessary to check the air conditioning refrigeration copper pipe regularly to reduce the chance of fluorine leakage in R410a air conditioning copper pipes, and also reduce the shrinkage or cracking of air conditioning copper pipes due to insufficient refrigerant.
 
 
To avoid frost on the outdoor unit air conditioning connection copper pipe, it is necessary to regularly check whether the protective film of the air conditioning connection copper pipe is damaged, which can reduce the frost phenomenon of the air conditioning connection copper pipe due to long-term outdoor use.
 
Clean the air conditioner regularly to avoid dust and fine substances being brought into the air conditioning copper pipe during the air conditioning refrigeration process, protect the cleanliness of the air conditioning copper pipe, prevent leakage of the air conditioning copper pipe due to bacteria, and extend the service life of the air conditioning copper pipe.
 

 

 

Plant and equipment

 
1
2
3
 
4
 
5
 
6
7
 
8
 
9
 
10
 

Packaging and shipping

 
5
1
2
3
4
 

Customer visits

 
1
2
3
4
5
6
7
8
9
10

GNEE is an enterprise engaged in the research, smelting and processing of copper and copper alloys. The factory covers an area of 350,000 square meters, and now has a series of production equipments such as vacuum induction furnace imported from the United States, vacuum consumable arc furnace made in Germany, 2800mm four-high reversible rolling mill, vacuum annealing furnace, and so on, which can customize the production of any size of plate within 2.6m * 16m, and the maximum length of a single pipe can reach 15m.
Meanwhile, we also have more than 100 sets of various testing instruments, the main equipment includes American non-destructive testing system, spectral analyzer, carbon and sulfur tester, universal testing machine, ultrasonic testing system, fatigue testing machine and so on.
With more than 10 years of export experience, our products are exported to USA, UK, Germany, France, Brazil, Japan, Korea, India, Vietnam, Australia, Philippines, Zambia, Indonesia and other countries.

Contact us today for a quotation:sales@gneesteel.com
20250716165456

 

Hot Tags: air conditioning copper pipes, China air conditioning copper pipes manufacturers, suppliers, factory

Send Inquiry

whatsapp

Phone

E-mail

Inquiry