C26000 70/30 Annealed Brass Capillary Tube for Radiators

C26000 Cartridge Brass Capillary Tube

C26000 is the UNS number for cartridge brass, the 70 % copper and 30 % zinc alloy whose deep drawing behaviour made it the classic material for cartridge cases and which now serves a much wider range of formed and drawn components. In capillary form the alloy is drawn down to a small outside diameter with a closely controlled bore, then annealed to the temper needed for coiling and installation.

Capillary tube earns its name from the internal bore that meters flow by restriction rather than by a valve. Radiator and refrigeration circuits use it to control refrigerant flow and to equalise pressure, while instrument and lubrication systems use the same small bore tubing to carry a signal or a small fluid volume with minimal dead volume.

Composition and Material Identity

Element Cu Zn Pb Fe Other elements
Weight % 68.5 - 71.5 Remainder 0.07 max 0.05 max 0.15 max

The narrow copper range is the key to consistent forming behaviour: the alloy must sit in the single-phase alpha region so that wall thinning during deep drawing and capillary reduction remains uniform along the length of the coil.

Physical and Mechanical Properties

Property Typical value
Density 8.5 - 8.6 g/cm³
Melting range (solidus to liquidus) approx. 915 - 955 °C
Electrical conductivity (annealed) 28 - 32 % IACS
Thermal conductivity at 20 °C approx. 115 - 120 W/(m·K)
Modulus of elasticity in tension approx. 110 GPa
Machinability rating (free-cutting copper = 100) 30
Temper Tensile strength Yield strength Elongation
Annealed, O60 300 - 380 MPa 100 - 150 MPa 45 % min
Half hard, H02 430 - 520 MPa 320 - 400 MPa 15 - 25 %
Hard, H04 520 - 620 MPa 430 - 520 MPa 5 - 12 %

Capillary tube is almost always supplied annealed, because the coil must be bent to shape by the appliance builder and the bore must remain round and unobstructed. The higher tempers are used for flat strip and formed hardware rather than for metering tube.

Capillary Tube Dimensions and Tolerances

Parameter Typical range Notes
Outside diameter 1.5 - 12.7 mm Coiled or straight
Wall thickness 0.3 - 1.2 mm Uniformity critical for coiling
Inside diameter 0.5 - 6.0 mm Controlled for metering duty
Coil length up to 50 m Level wound or random wound
Straight length 1 - 6 m For fabrication shops

For flow-control applications the inside diameter determines the metering characteristic, so diameter tolerance and bore cleanliness are agreed at order stage and checked coil by coil. Tubes are supplied cleaned, dried and capped so that no drawing lubricant or moisture reaches the refrigerant circuit.

Annealing and Processing

Annealing after cold reduction takes place in the range of 425 - 600 °C, the exact figure depending on the amount of cold work and the temper required. Atmosphere control matters, because an oxidised or carbon-contaminated surface on a capillary bore is difficult to remove and changes flow behaviour. TIG welding and resistance welding are both used for joints, and furnace or induction brazing works well, but zinc fume generation must be avoided by keeping heat input under control.

Machining, where the tube is cut or flared, benefits from sharp tooling and light lubricant; the alloy work-hardens readily and a dull tool will produce burrs that restrict the bore. Capillary ends are deburred and gauged after cutting, and coils are sleeved for transport so the bore is not deformed.

Applications

Refrigerant metering and pressure equalising lines in refrigeration and air conditioning equipment

Automotive and industrial radiator cores and fuel systems

Thermostatic controls and small fluid metering devices

Instrumentation lines requiring minimum dead volume

Lubrication feed lines to bearings and gearboxes

Precision stamped and formed components such as fasteners, springs, connectors and terminals

Architectural trim and decorative hardware in low-corrosion environments

Inspection Points Before Dispatch

Chemical certificate confirming copper inside 68.5 - 71.5 %

Inside and outside diameter gauging along the full coil

Mechanical test confirming the annealed temper and elongation

Cleanliness verification: no drawing lubricant, moisture or loose particles in the bore

Pressure or leak test where the tube is rated for refrigerant duty

Visual check for dents, kinks and surface defects before coiling and packing

FAQ

Q: What does 70/30 mean for C26000?
It describes the nominal analysis of cartridge brass: about 70 % copper and 30 % zinc, held in specification between 68.5 and 71.5 % copper.

Q: Why is capillary tube supplied annealed?
The annealed temper lets the appliance builder coil, bend and flare the tube without cracking, and it keeps the bore round so the metering characteristic stays stable.

Q: How is the flow rate of a capillary tube controlled?
Flow is set by the inside diameter and length of the bore. Both are specified on the order and verified by gauging, since small diameter changes shift the metering rate noticeably.

Q: Is C26000 suitable for outdoor use?
It resists atmospheric and freshwater corrosion well and is widely used indoors and in protected outdoor locations; in aggressive marine or industrial atmospheres a protective coating or a different alloy is considered.

Q: What annealing temperature is used after cold working?
Annealing is carried out in the range of 425 - 600 °C, selected according to the cold reduction and the temper the customer requires.

Q: Why does bore cleanliness matter so much?
Residue in a capillary bore changes the pressure drop, and in a refrigeration circuit it can block the metering path. Tube is therefore cleaned, dried and capped before dispatch.