ASTM B42 seamless copper pipe in C11000 electrolytic tough pitch copper is a hollow round section supplied for air conditioning, refrigeration and general engineering service. The bore runs open along the full length of the product, so the pipe combines a large internal surface area with the thermal and electrical behaviour of high conductivity copper. That combination is the reason the material is widely used for condensers, evaporators, connecting lines and the transport of water, gas and oil.
What Is ASTM B42 C11000 ETP Copper Pipe?
ASTM B42 specifies seamless copper pipe in standard nominal sizes with controlled wall thickness. C11000 is the UNS designation for electrolytic tough pitch copper, a material of at least 99.90 % copper that is refined electrolytically and cast with a small, deliberately controlled oxygen level. The residual oxygen is present as finely dispersed cuprous oxide and does not materially reduce thermal or electrical performance in normal air conditioning, plumbing and industrial duty.
Air conditioning and refrigeration coils are usually ordered to ASTM B280 or ASTM B188, because those specifications define the cleaned, capped and dehydrated tube that field brazing requires. ASTM B42 pipe remains the correct specification for larger standard size pipe runs, headers, manifolds and general engineering pipework joined by soldering, brazing or mechanical fittings.
Chemical Composition and Typical Physical Properties
| Item | Value | Remark |
|---|---|---|
| Copper (Cu) | 99.90 % min | Electrolytic tough pitch grade |
| Oxygen (O) | 0.02 – 0.06 % typical | Held as cuprous oxide particles |
| Other elements, total | 0.10 % max | Silver, lead, iron and similar residuals |
| Density | 8.94 g/cm³ | At 20 °C |
| Melting point | about 1083 °C | Pure copper melting point |
| Electrical conductivity | 101 % IACS typical | Annealed condition |
| Electrical resistivity | 1.71 – 1.72 × 10⁻⁸ Ω·m | At 20 °C |
| Thermal conductivity | about 385 W/(m·K) | At 20 °C |
| Specific heat capacity | 0.385 kJ/(kg·K) | At 20 °C |
The figures above are typical published values for annealed C11000 copper. They explain why the grade is chosen where heat must move quickly across a thin wall and where joints must stay sound over decades of thermal cycling.
Standard Sizes, Wall Thickness and Temper
| Parameter | Range or Options |
|---|---|
| Outside diameter (OD) | 4 mm – 150 mm |
| Wall thickness | 0.25 mm – 8 mm |
| Length | 1 m – 6 m straight, or coils as required |
| Common ACR sizes | 1/4 in, 3/8 in, 1/2 in, 5/8 in, 3/4 in, 7/8 in, 1-1/8 in |
| Form | Seamless, hollow round pipe and tube |
| Temper | O60 soft annealed, H58 light drawn, H80 hard drawn |
| Ends | Plain, capped or plugged; bevelled on request |
| Delivery form | Straight length, pancake coil, level wound coil |
Soft annealed pipe is bent and flared without cracking and is preferred for coil and connecting line duty. Light drawn and hard drawn pipe holds its shape in straight runs, valve stations and manifolds, where rigidity helps to keep hangers and supports simple.
Why C11000 Copper Suits Air Conditioning and Refrigeration Duty
High thermal conductivity: heat crosses the wall quickly, so evaporator and condenser coils reach working capacity with less surface area.
High electrical conductivity: bonding and earthing continuity through the refrigerant circuit is straightforward.
Excellent formability: the tube can be expanded into tube sheets, bent to tight radii and flared for mechanical joints.
Good corrosion behaviour: a protective patina forms in most atmospheric and neutral water environments.
Pressure capability: wall thickness can be matched to working pressure, so the same alloy serves suction lines and high side liquid lines.
Clean bore: dehydrated, capped product keeps moisture and mill scale out of a refrigeration circuit before charging.
Fabrication, Cleaning and Quality Control
Tubes are produced seamless by extrusion and cold drawing, then annealed, pickled and drawn to final size.
Bores are purged and capped so that residual moisture and nitrogen carry-over stay within specification for refrigeration use.
Inspection covers dimension and wall thickness measurement, visual and bore examination, tensile testing of the finished temper and, where requested, eddy current testing and hydrostatic pressure testing.
Certificate types are issued as manufacturer test certificates, with third party witness or laboratory testing available on request.
Handling keeps tube ends protected and stacks dry during storage and transport to avoid mechanical damage and surface staining.
FAQ
Q: Is ASTM B42 the correct standard for air conditioning coils?
ASTM B42 covers seamless copper pipe in standard sizes. Small diameter field installed air conditioning and refrigeration coils are normally ordered to ASTM B280 or ASTM B188, while B42 pipe is used for larger standard size runs and fabricated assemblies.
Q: Why is C11000 called tough pitch copper?
Because the melt is only partly deoxidised, a small and controlled amount of oxygen remains in the metal. Electrolytic refining before casting keeps the copper at 99.90 % minimum purity, so conductivity stays close to the 101 % IACS reference level.
Q: What wall thickness should be selected?
Wall thickness follows the design pressure, the outside diameter and the amount of bending the tube must survive. Walls from 0.25 mm to 8 mm are available, and thinner walls are chosen for heat transfer duty while thicker walls are used for higher pressure and mechanical strength.
Q: Can the pipe be welded?
Yes. C11000 is readily soldered, brazed and welded. Brazing with a phosphorus bearing filler is common for refrigerant circuits because it avoids the need for flux inside the bore and leaves a clean joint.
Q: What temper is best for bending?
Soft annealed O60 temper gives the greatest ductility and is used for bending and coiling. Light drawn H58 and hard drawn H80 tempers are chosen when dimensional stability and higher strength matter more than bendability.
Q: How is the tube protected before installation?
Bores are dehydrated and ends are capped or plugged, and bundles are wrapped for transport. Caps should stay in place until the installation moment so that moisture, dust and construction debris cannot enter the circuit.