ASTM B111 C12200 DHP Copper Coil for Heat Exchangers

C12200 DHP Copper Coil for Heat Exchange Equipment

Copper coil is the practical delivery form when a heat exchanger, chiller or refrigeration circuit has to be assembled on site or in a production cell without long straight tube runs and numerous joints. ASTM B111/B111M defines the seamless copper tube used for heat-transfer duty, and UNS C12200 - deoxidised high phosphorus copper, or DHP - is the grade normally wound into these coils.

The grade contains 99.90 percent minimum copper and 0.015 to 0.040 percent phosphorus. Phosphorus deoxidises the metal, which is what allows it to be brazed and welded without hydrogen embrittlement, and it also promotes a fine grain size that survives repeated bending. The result is a coil that can be uncoiled, bent and joined reliably in a wide range of field conditions.

Supply Forms and Specification Data

Item Range or requirement
Coil type pancake coil for small diameters; level wound coil for larger diameters and long runs
Outside diameter 4 mm to 108 mm, coil-specific
Wall thickness 0.5 mm to 4 mm
Tempers O60 soft annealed, O50 light annealed, H55 light drawn, H58 drawn, H80 hard drawn
Composition Cu (including Ag) 99.90 % min; P 0.015-0.040 %
Standards ASTM B111/B111M, ASME SB111; ASTM B75 for general seamless tube; EN 12451 for Cu-DHP
Testing eddy current, hydrostatic or pneumatic pressure, expansion and flattening

Mechanical and Physical Properties

Property Typical value
Tensile strength, annealed 207 MPa (30 ksi) minimum
Tensile strength, light drawn H55 250 MPa minimum, yield 205 MPa
Tensile strength, hard drawn H80 310 MPa minimum, yield 275 MPa
Elongation, annealed 35 % minimum
Density 8.90 g/cm³ at 20 °C
Melting point 1083 °C
Thermal conductivity 290-365 W/(m·K) at 20 °C
Electrical conductivity 70-90 % IACS depending on temper

Applications

Industrial heat exchangers, condensers and evaporators supplied as coiled tube for site assembly.

HVAC systems and refrigeration units, including split-system and packaged equipment.

Water heaters and solar thermal panels.

Steam-to-water and steam-to-air heat transfer systems.

General piping and fluid distribution in corrosion-sensitive facilities.

Chilled-water circuits, fan coil units and heat pumps.

Working with Coiled Tube

Coils arrive soft and are uncoiled through a straightener or by hand, then cut to length, bent and joined. Brazing is the normal jointing method for refrigeration and HVAC circuits; soldering is equally acceptable for lower-pressure water systems. Because the alloy tolerates heat well, joints can be made without pre-annealing and without the risk of cracking associated with oxygen-bearing copper. Where a bend is made after the tube has been straightened and work hardened, a local anneal at 250 °C to 650 °C restores the ductility needed for the next operation.

Cleanliness before brazing matters as much as the filler metal. Tube ends should be cut square, deburred and wiped free of oil; a dry nitrogen purge should be used inside the tube while brazing refrigeration circuits, so that no internal oxide scale forms. After assembly, the circuit should be pressure tested and evacuated to the level required by the system design.

Inspection and Storage Notes

Check coil weight, coil dimensions and the number of wraps against the order, and confirm that the temper designation is recorded on the mill certificate.

Verify eddy-current and pressure test reports, and confirm dimensional tolerances on wall thickness, because these control the burst pressure of the finished circuit.

Keep coils indoors, dry and wrapped; damp storage causes tarnish and, in chloride-bearing air, surface pitting.

Do not lift coils by the free end, and avoid tight kinks during uncoiling, because they reduce wall thickness at the bend.

FAQ

Q: What is the difference between a pancake coil and a level wound coil?
A pancake coil is wound in a flat spiral, usually for small diameters and short runs. A level wound coil is wound layer on layer on a spool or former and is used for larger diameters and long uninterrupted lengths.

Q: Which temper should be ordered for a refrigeration circuit?
Soft annealed tube is usual, because the installer has to bend and route the coil on site. Drawn tempers are selected for straight sections or where the circuit operates at higher pressure.

Q: Why is dry nitrogen purging needed during brazing?
It displaces air inside the tube so that no oxide scale forms on the bore. Internal scale later breaks loose, blocks expansion devices and contaminates the refrigerant circuit.

Q: Is C12200 coil suitable for potable water?
The grade has good resistance to most waters and is widely used in water heating and plumbing circuits. The specific water chemistry should be reviewed where aggressive or high-chloride supplies are involved.

Q: How is coil length specified?
By coil weight or by total length, together with outside diameter, wall thickness, temper and coil dimensions. Agreeing all five points at the order stage avoids scrap during assembly.

Q: What documentation is provided?
Mill test certificates quoting heat analysis and mechanical properties, together with eddy-current and pressure test records, so the coil can be traced through fabrication and commissioning.